![usb block 1.6.1 usb block 1.6.1](https://cdn-shop.adafruit.com/1200x900/3972-03.jpg)
- #Usb block 1.6.1 update#
- #Usb block 1.6.1 driver#
- #Usb block 1.6.1 manual#
- #Usb block 1.6.1 software#
Slovak browsers show Czech localization by default now.įixed: Write functions in web interface did not work with higher HTTP security disabled.įixed: Bug with incorrect white space evaluation. The softstart (meant for heat pumps or vehicle chargers) could run without assigned priority.įixed: Relay consuption optimizer did not work.įixed: Reset energy checkbox for ANDI inputs in the web interface did not work.įixed: Reaction on Accept-Language HTTP header. Wrong value was shown after reset and configuration write.įixed: Problem with PWM output mode with minimum power greater than zero. Modified: PT1000 temperature calculation to be more precise.įixed: Wrong digital temperature sensor search (one sensor at two or more positions).įixed: Realtime chart configuration did not survive device restart.įixed: ANDI function not configured correctly after configuration write when changing from PT1000 to another function or vice versa.įixed: Sometimes upon ANDI function change the ANDI hardware was not switched correctly just after writing the configuration, and device restart was needed.įixed: Bug in ANDI power calculation when ANDI was set to S0 pulse counter. WATTconfig Mx 2.0 for iOS: available on App StoreĪdded: It is possible to use remote control mode (with inserted sc-router), behavior is the same as for WATTrouter ECO.Īdded: Content-Disposition HTTP header to HTTP requests sent by the device when performing the web client data exchange. WATTconfig Mx 2.0 for Android: available on Google Play
#Usb block 1.6.1 manual#
User manual corresponding to this version Lower prio relay did not prepend when higher prio relay was restricted by time schedule.įixed: wrong behavior of power measurement at higher frequencies than 50Hz.įixed: Caching of static webserver files.įixed: Temperature sensor failure no longer blocks entire control but only respective time schedules. Removed: Wireless station table (Other settings tab).įixed: Bug in relay prepend calculation. Removed: Logical WLS outputs (Output settings tab). Removed: Measurement source (Input settings tab). Removed: SC-Router related error states (Error and info status). That's why we decided to move to 64-bit everywhere.Īdded: MODBUS protocol (RTU on RS485 line, TCP on Ethernet line).Īdded: Indicator for external output switching (Output status pane).Īdded: SD card error indicator (Error and info status).Īdded: S-Connect device error indicator (Error and info status).Īdded: binary input function for ANDI inputs (Input settings tab).Īdded: Duplicate to input field (Output status pane).Īdded: Measured by input field (Output settings tab).Īdded: Low tariff input settings (Other settings tab).Īdded: RS485 settings (Other settings tab).Īdded: Input settings for statistics (Other settings tab).Īdded: Logical inputs and outputs needed for S-Connect protocol. The main reason for this change was MacOS Catalina, which dropped 32-bit support entirely. Since version 1.6 we provide only 64-bit versions of WATTconfig software, up to version 1.5 they are 32-bit.
![usb block 1.6.1 usb block 1.6.1](https://images-na.ssl-images-amazon.com/images/I/513yO-jH8NL._AC_SL1500_.jpg)
However, it can work in other OS versions or other Linux distributions.
#Usb block 1.6.1 software#
The WATTconfig software runs on Windows 7 and later, Ubuntu 16.04 and later, OS X 10.11 El Capitan and later.
#Usb block 1.6.1 update#
Please always update BOTH software and firmware for your device!
#Usb block 1.6.1 driver#
Note: Please in case of communication problems always upgrade this driver to the newest version! Regulator firmware and software WATTconfig Mxīefore updating please always read the newest user manual. H1]Updates for WATTrouter Mx USB interface driver